STATLX(1)                USER COMMANDS                  STATLX(1)



NAME
     statlx - input lx signal from SFS data file  and  create  lx
     statistics table

SYNOPSIS
     statlx (-f minimum frequency)  (-F  maximum  frequency)  (-s
     statistics file) (dbase file)

DESCRIPTION
     statlx Is a program to input an lx signal, derive statistics
     concerning  the  number  of  periods  with given tx and open
     phase, and store these statistics in an output  file,  which
     can  be  read  and  displayed  in various formats by program
     stat_disp. The program while running  outputs  to  the  user
     terminal  a sequence of numbers giving the average level for
     each buffer relative to a threshold below which  the  signal
     is assumed to consist of silence: thus a signal level number
     less than 1 indicates that the current buffer is assumed  to
     consist of silence, and will be ignored.

     Options and their meanings are:

     -I         Identify program and exit

     -fminimum frequency
                Select minimum Fx to be  recognised  by  program.
                Intervals between excitations
                 longer than this minimum frequency will be  con-
                sidered as voiceless. Default
                 minimum frequency is 40 Hz.

     -Fmaximum frequency
                Select maximum Fx to be  recognised  by  program.
                Default is 800 Hz

     -sstatistics file
                name of statistics file. Default is "stat_table"

     -iitem number

OUTPUT ITEMS
     3          Tx and other Lx parameters

BUGS
     None known

VERSION/AUTHOR
     1.0 - Andrew Breen ( form v2.0 inlx P.Davis)

SOURCE
     /users/mark/sfs/man/../ucl/statlx.c




Sun Release 4.1         Last change: UCL                        1